2m*3mm 10%聚乙二醇己二酸酯/401有機擔體填充柱
產(chǎn)品名稱:2m*3mm 10%聚乙二醇己二酸酯/401有機擔體填充柱
產(chǎn)品型號:2m*3mm
產(chǎn)品廠商:浩瀚色譜(山東)應用技術開發(fā)有限公司
簡單介紹
10%聚乙二醇己二酸酯/401有機擔體填充柱,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦爐煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑
2m*3mm 10%聚乙二醇己二酸酯/401有機擔體填充柱的詳細介紹
10%聚乙二醇己二酸酯/401有機擔體填充柱
10%聚乙二醇己二酸酯/401有機擔體填充柱 詳細信息:












10% polyethylene glycol adipate/401 organic support packed column
10% polyethylene glycol adipate/401 organic support packed column Details:
Name: Packed Column
Fixative ·: 10% polyethylene glycol adipate
Carrier: 401 organic carrier (0.25mm-0.18mm)/60-80 mesh
Ratio: Carrier: Fixative = 100:10
Model: 10%PEA/401
application:
GBT 12717-2007 Test methods for industrial acetates
GBT 12589-2007 Chemical reagent Ethyl acetate
GBT 12589-1990 Chemical reagent Ethyl acetate
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. developed a 10% polyethylene glycol adipate/401 organic support packed column for the determination of ethyl acetate, with high column efficiency, good separation, air, moisture, ethanol and ethyl acetate The esters were effectively separated, and the results were accurate and reliable.
10% polyethylene glycol adipate/401 organic support packed column Test spectrum:
10%聚乙二醇己二酸酯/401有機擔體填充柱 詳細信息:
名稱:填充柱
固定液·:10%聚乙二醇己二酸酯
擔體:401有機擔體(0.25mm-0.18mm)/60-80目
配比:載體:固定液=100:10
型號:10%PEA/401
應用:
GBT 12717-2007 工業(yè)用乙酸酯類試驗方法
GBT 12589-2007化學試劑 乙酸乙酯
GBT 12589-1990 化學試劑 乙酸乙酯
浩瀚色譜(山東)應用技術開發(fā)有限公司,研發(fā)的10%聚乙二醇己二酸酯/401有機擔體填充柱測定乙酸乙酯時,柱效高,分離好,空氣,水分,乙醇和乙酸乙酯得到有效分離,結果準確。
10%聚乙二醇己二酸酯/401有機擔體填充柱 測試譜圖:












10% polyethylene glycol adipate/401 organic support packed column
10% polyethylene glycol adipate/401 organic support packed column Details:
Name: Packed Column
Fixative ·: 10% polyethylene glycol adipate
Carrier: 401 organic carrier (0.25mm-0.18mm)/60-80 mesh
Ratio: Carrier: Fixative = 100:10
Model: 10%PEA/401
application:
GBT 12717-2007 Test methods for industrial acetates
GBT 12589-2007 Chemical reagent Ethyl acetate
GBT 12589-1990 Chemical reagent Ethyl acetate
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. developed a 10% polyethylene glycol adipate/401 organic support packed column for the determination of ethyl acetate, with high column efficiency, good separation, air, moisture, ethanol and ethyl acetate The esters were effectively separated, and the results were accurate and reliable.
10% polyethylene glycol adipate/401 organic support packed column Test spectrum:
相關產(chǎn)品
在線留言 |